page_banner

Products

HIV 1/2/O Tri‐line Human Immunodeficiency Virus Rapid Test Device/Strip


Short Description:

The HIV 1/2/O Tri-line Human Immunodeficiency Virus Rapid Test Device/Strip (Whole Blood /Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies to HIV-1, HIV-2, and Subtype O in whole blood, serum or plasma to aid in the diagnosis of HIV infection.



Product Detail

Product Tags

Principle

The HIV 1/2/OTri‐lineHuman ImmunodeficiencyVirusRapid TestDevice / Strip (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of antibodies to HIV‐1,HIV‐2, and SubtypeO in whole blood, serum or plasma. The membrane is pre‐coated withrecombinantHIV antigens in the testlineregions,T1 and T2. The T1 testlineis pre‐coatedwithHIV‐1 and SubtypeO antigenand the T2 testline is pre‐coatedwithHIV‐2 antigen.During testing,the wholeblood, serum or plasma specimen reactswithHIV antigen coated particles in the test strip.The mixture then migrates upward on the membrane chromatographically by capillary actionand reactswith recombinantHIV antigen on the membrane in the testline region.If the specimen contains antibodies to HIV‐1 and/or SubtypeO, or HIV‐2, one colored linewill appear in the testline region; if the specimen contains antibodies to HIV‐1 and/or SubtypeO, and HIV‐2,two colored lineswill appear in the test line region.Bothindicate a positive result. If the specimen does not containHIV‐1, SubtypeO, and/orHIV‐2 antibodies, no colored linewill appear in the testline region indicating a negative result.To serve as a procedural control, a coloredlinewill always appear in the controlline region indicating that proper volume of specimen has been added and membranewickinghasoccurred.

Procedure

DIRECTIONS FOR USE:

HIV 1/2/O Tri‐line Human Immunodeficiency Virus Rapid Test Device
Allow the test device, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.

1. Remove the test device from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Place the test device on a clean and level surface.

For Serum, Plasma or Venipuncture Whole Blood specimens: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 80 μL) to the specimen well (S) of the test device, then add 1 drop of buffer (approximately 40 μL) and start the timer.
For Fingerstick Whole Blood specimens: Fill the capillary tube and transfer approximately 50 μL of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 1 drop of buffer (approximately 40 μL) and start the timer.
3. For hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 50 μL) to fall into the center of the specimen well (S) on the test device, then add 1 drop of buffer (approximately 40 μL) and start the timer.
4. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 20 minutes

HIV 1/2/O Tri-line Human Immunodeficiency Virus Rapid Test Strip

Allow the test strip, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.

1. Remove the test strip from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.

For Serum, Plasma or Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of serum, plasma or venipuncture whole blood (approximately 80 μL) to the 'Specimen Pad' of the test strip, then add 1 drop of buffer (approximately 40 μL) and start the timer.

For Fingerstick Whole Blood specimen:

To use a capillary tube: Fill the capillary tube and transfer approximately 80 μL of fingerstick whole blood specimen to the 'Specimen Pad' of the test strip, then add 1 drop of buffer (approximately 40 μL) and start the timer.
To use hanging drop: Allow 2 hanging drops of fingerstick whole blood specimen to fall into the center of the 'Specimen Pad' on the test strip, then add 1 drop of buffer (approximately 40 μL) and start the timer.
2.Wait for the colored line(s) to appear. The result should be read at 15 minutes. Do not interpret results after 20 minutes.

Interpretation Of Results

HIV1&/orO Positive:* The coloredlinein the controlline region(C) appears and a colored line appears in testline region 1 (T1).The resultis positive for HIV1&/orOinfection

HIV2 Positive: * The colored line in the controlline region (C) appears and a colored line appears in test line region 2 (T2).The resultis positive forHIV 2 infection

HIV 1&2 &/or O Positive: * The colored line in the control line region (C) appears and two colored lines should appear in testline regions 1 and 2 (T1 and T2). The color intensities of the lines do not have to match. The result is positiveforHIV1&2&/orO infection.

sabds
vsdvs

The colored line in the control line region (C) appears.No line appears in test lineregions1 or2 (T1orT2).

vsdvs

Controlline(C) fallsto appear.Insufficientbuffer volumeor incorrect procedural techniques are the most likely reasons for control line failure.

Review the procedure and repeatthe procedure with a new test strip. If the problem persists, discontinue using the test kit immediately and contact your localdistributor.

*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of HIV antibodies present in the specimen. Therefore, any shade of colored in the test region (T) should be considered positive.